In short: A girder truss carries other trusses. Where it is not supported the way the engineering requires, a large part of the roof is being carried by something that was not designed for it.

The girder truss is not an ordinary truss

It collects load from the trusses that frame into it, which means its support is carrying a concentrated load rather than a distributed one. We have recorded a girder truss not supported where the engineering requires on a Rockbank build. It is the single highest-consequence frame item we find.

Strap bracing that was never tensioned

Metal strap bracing installed but not tensioned is present, visible and contributing nothing. Tension is the mechanism. Without it the strap is decoration, and it photographs as complete.

Top plate to stud anchors

Missing where the engineer prescribed them. Another link in the chain from roof to slab, another item that costs a few dollars at frame stage.

And below the frame

Vapour barrier not extended beneath the whole slab, and bars missed to loadbearing ribs beyond the prescribed span. Across Accolade, Arcadia, Atlas and the surrounding City of Melton releases, the pattern is consistent enough that we check these specifically.

Written by our local inspection team from work carried out in Rockbank. Licensed building practitioners.

Blog

More from the Rockbank blog

All posts →

Book a building inspection in Rockbank

Instant online pricing for Rockbank, or contact the booking team.

FAQ

Questions Rockbank owners ask about this

How serious is an unsupported girder truss?

Potentially very. It is reported for the engineer to confirm rather than judged on site, and it is not something to leave until handover.

Can strap bracing be tensioned later?

While the frame is open, easily. Once lined, not without opening it.